The Efficia CM10 patient monitor displays ECG, basic arrhythmia, ST analysis, SpO2 noninvasive blood pressure (Philips FAST SpO2, Masimo rainbow SET*, or Nellcor OxiMax), dual temperature, and impedance respiration. Depending on your selections, the monitors can also help you measure:
• Dual invasive blood pressure
• Sidestream CO2 (Respironics LoFlo, Respironics CapnoTrak
and Microstream) or Mainstream (Respironics Capnostat)
• Enhanced arrhythmia analysis
Philips Efficia CM10 Patient monitor Specifications:
- Time-tested physiological measurements relied on for over 200 million patients every year
- Reliable Philips Efficia consumables, available in cost-effective bundles or through a delivery service that helps simplify your ordering logistics
- Solidly built and reliable, able to handle heavy workloads, physical knocks and electrostatic interference
- Ready for plug-and-play connectivity to Philips Efficia central monitoring
- Built-in HL7 connectivity to interface with hospital Information systems
Philips Efficia CM10 Features and benefits
• 10‑inch color screen with large numerics and waveforms (touchscreen optional)
• Easy selection of different display layouts
• Retrospective clinical information review from up to 240 hours of tabular and graphical trends and optional 48 hours full disclosure
• Lithium‑ion battery, with practical access slots – making it simple to change the battery (with a standard, flat-head screwdriver)
• Audible and visual alarm indicators
• Compatible with a wide range of Philips supplies and accessories
• Connectivity to Efficia rack and modules
• Connectivity to central station
• Interface to other systems using HL7 data over the serial connection, or LAN/optional WLAN
• Password‑protected administrator and maintenance
• Easy software upgrades over the USB port
• Automatic or prompted patient ID entry using the optional barcode scanner support
• Optional integrated recorder for easy printing of patient data
• Optional roll stand, or wall mounts
Other Specification of Philips Efficia Cardiac Monitor:
Brand | Philips |
Series | Efficia |
Model | CM10 |
Width | 27 cm (10.6 in) |
Height | 22 cm (6.6 in) |
Depth | 17 cm (6.7 in) |
Weight (with no battery) | < 3.3 kg (7.0 lb) |
Display | Type: 25.6 cm (10.1 in) LCD |
Resolution | 1280 active pixels/line, 800 active lines/frame |
Viewing angle | ± 15 |
Battery | Weight, 3‑cell, lithium‑ion: 0.25 kg (0.55 lb), 9‑cell, lithium‑ion: 0.5 kg (1.1 lb) |
Channels | 4 |
Recorder type | thermal |
Paper width | 58 mm |
User selectable speeds | 6.25, 12.5, 25 and 50 mm/s |
Alarms | Three alarm severity levels (high, medium, low) with corresponding visual and audio indicators |
ECG | |
Heart rate range | Adult: 15 – 300 bpm, Pediatric and neonatal: 15 – 350 bpm |
Heart rate accuracy | ± 1% or ± 1 bpm |
Leads | 3‑lead and 5‑lead |
Pacemaker detection | Indicator of pace pulse on the waveform display |
Invasive blood pressure | |
Measurement range | -40 to 360 mmHg |
Input sensitivity | 5 µV/V/mmHg |
Accuracy | ± 1% |
Drift: | less than 0.05%/° C |
Warm-up time | < 15 seconds |
Noninvasive blood pressure (NBP) | |
Method | Oscillometric |
Adult measurement range | Systolic: 30 – 270 mmHg (4.0 – 36.0 kPa), Diastolic: 10 – 245 mmHg (1.3 – 32.7 kPa), MAP: 20 – 255 mmHg (2.7 – 34.0 kPa) |
Pediatric measurement range | Systolic: 30 – 180 mmHg (4.0 – 24.0 kPa), Diastolic: 10 – 150 mmHg (1.3 – 20.0 kPa), MAP: 20 – 160 mmHg (2.7 – 21.3 kPa) |
Neonatal measurement range | Systolic: 30 – 130 mmHg (4.0 – 17.3 kPa), Diastolic: 10 – 100 mmHg (1.3 – 13.3 kPa), MAP: 20 – 120 mmHg (2.7 – 16.0 kPa |
Blood pressure accuracy | Maximum standard deviation: ≤ 8 mmHg, Maximum mean error: ± 5 mmHg |
Pulse rate range | 40 – 300 bpm |
Pulse rate accuracy | 40 – 100 bpm: ± 5 bpm, 101 – 200 bpm: ± 5% of reading, 201 – 300 bpm: ± 10% of reading |
Initial cuff inflation | Adult: 160 mmHg (21.3 kPa), Pediatric: 140 mmHg (18.7 kPa), Neonatal: 100 mmHg (13.3 kPa) |
NBP intervals | Automatic measurements at intervals of 1, 2, 3, 5, 10, 15, 30, 60, 90, 120 minutes and STAT |
Temperature measurements | |
Measurement range for all measurement sites | 0° to 50° C (32° to 122° F) |
Accuracy | ± 0.1° C – without a temperature probe |
Mode of operation | Direct mode |
Heating and cooling transient response time | ≤ 150 s |
Microstream CO2 | |
Measurement range | 0 – 150 mmHg |
Data sample rate: | Waveform sampling, 20 samples per second |
Flow rate | 50 ml/min, + 15 ml/min, –7.5 ml/min |
CO2 waveform resolution | 0.1 mmHg |
etCO2, imCO2 resolution | 1.0 mmHg |
Initialization and power-up time | 40 seconds (typical), 3 minutes maximum |
Total response time for adults/paediatrics | 3.9 seconds, for 10% – 90% changes in CO2 concentration |
Maximum CO2 response time | 5.3 seconds (typical) |
Calibration interval | Initial calibration after one year or 1,200 hours |
Leak tightness | < 250 mBar/min |
Accuracy (for respiratory rates up to 80 rpm) | ± 2 mmHg in the range 0 mmHg – 38 mmHg, ± 5% of reading + 0.08% for every 1 mmHg above 38 mmHg in the range 39 mmHg – 150 mmHg |
Respiration rate range | 0 – 150 rpm |
Respiration accuracy | ± 1 rpm in the range 0 – 70 rpm, ± 2 rpm in the range 71 – 120 rpm, ± 3 rpm in the range 121 – 150 rpm |
Effects of cyclical pressure | Overpressure: + 100 cmH2O, Underpressure: –20 cmH2O |
Mainstream CO2* | |
Measurement range | 0 – 150 mmHg** |
ImCO2 measurement range | 3 – 50 mmHg |
Data sample rate | Waveform sampling, 20 samples per second |
CO2 waveform resolution | 0.1 mmHg |
etCO2, imCO2 resolution | 1.0 mmHg |
Initialization time | Full specification etCO2 measurement displays after warm-up, in less than 2 minutes |
Total response time | < 2 seconds |
Calibration interval | No calibration required |
Auto zero interval | Only required when changing the airway adapter style |
Accuracy (gas temperature at 35° C) | ± 2 mmHg in the range 0 – 40 mmHg, ± 5% of reading in the range 41 - 70 mmHg, ± 8% of reading in the range of 71 – 100 mmHg, ± 10% of reading in the range of 101 – 150 mmHg |
Respiration rate range | 0 – 150 rpm |
Respiration rate accuracy | ± 1 rpm |
Drift of measurement accuracy | Short-term drift (4 hours of use): does not exceed 0.8 mmHg, Long-term drift (120-hour period): retains accuracy specification |
Barometric pressure | Configured by system administrator |
Impedance respiration | |
Method | Transthoracic impedance |
Measurement range | 3 – 150 rpm |
Resolution | 1 rpm |
Accuracy | ± 1 rpm in the range 3 – 120 rpm, ± 2 rpm in the range 121 – 150 rpm |
Respiration excitation waveform | < 250 μA, 37 kHz nominal |
ECG leads used | RA to LL |
Display sweep speeds | 6.25, 12.5, 25, 50 mm/s |
Leadoff condition | Detected and displayed |
ECG arrhythmia | |
Respiration excitation waveform | < 250 μA, 37 kHz nominal |
Time to alarm for tachycardia | < 5.0 seconds |
Tall T-wave rejection capability | Tested to a T-wave amplitude of 1.8 mV |
Heart rate meter accuracy and response to irregular rhythm | Ventricular bigeminy: 80 bpm, Slow alternating ventricular bigeminy: 60 bpm, Rapid alternating ventricular bigeminy: 120 bpm, Bidirectional systoles: 90 bpm |
Time to alarm for cardiac standstill | < 10 seconds |
Time to alarm for low heart rate | < 10 seconds |
Time to alarm for high heart rate | < 10 seconds |
Pacemaker pulse rejection | Rejects ± 2–± 700 mV; pulse widths 0.1 – 2.0 ms; with no overshoot |
List of Supplies with Cardiac Multipara Monitor:
Name of accessories | Quantity |
ECG Cable | 1 |
Spo2 Sensor | 1 |
NIBP Cuff (Adult) with Tube | 1 |
Temperature Sensor | 1 |
Power Cable | 1 |
User Manual | 1 |