Description

Philips Efficia is the best option when you are looking for a budget-friendly and high-quality patient monitor. Philips Efficia cm10 keep your budget under control because Philips Efficia cm10 price is the best price if you compare this monitor qualities to any other monitor: Having a choice of metrics to select from allows you to respond to changing patient situations. The physiological parameters created by Philips are used in Efficia patient monitors. You can expect the same high-quality experience from Efficia cm10 you've come to expect from Philips patient monitors. The primary monitoring feature of Philips cm10 monitor is based on proven precise and reliable Philips physiological measures.

The Efficia CM10 patient monitor displays ECG, basic arrhythmia, ST analysis, SpO2 noninvasive blood pressure (Philips FAST SpO2, Masimo rainbow SET*, or Nellcor OxiMax), dual temperature, and impedance respiration. Depending on your selections, the monitors can also help you measure:
• Dual invasive blood pressure
• Sidestream CO2 (Respironics LoFlo, Respironics CapnoTrak
and Microstream) or Mainstream (Respironics Capnostat)
• Enhanced arrhythmia analysis

Philips Efficia CM10 Patient monitor Specifications:
  • Time-tested physiological measurements relied on for over 200 million patients every year
  • Reliable Philips Efficia consumables, available in cost-effective bundles or through a delivery service that helps simplify your ordering logistics
  • Solidly built and reliable, able to handle heavy workloads, physical knocks and electrostatic interference
  • Ready for plug-and-play connectivity to Philips Efficia central monitoring
  • Built-in HL7 connectivity to interface with hospital Information systems
Philips Efficia CM10 Features and benefits

• 10‑inch color screen with large numerics and waveforms (touchscreen optional)
• Easy selection of different display layouts
• Retrospective clinical information review from up to 240 hours of tabular and graphical trends and optional 48 hours full disclosure
• Lithium‑ion battery, with practical access slots – making it simple to change the battery (with a standard, flat-head screwdriver)
• Audible and visual alarm indicators
• Compatible with a wide range of Philips supplies and accessories
• Connectivity to Efficia rack and modules
• Connectivity to central station
• Interface to other systems using HL7 data over the serial connection, or LAN/optional WLAN
• Password‑protected administrator and maintenance
• Easy software upgrades over the USB port
• Automatic or prompted patient ID entry using the optional barcode scanner support
• Optional integrated recorder for easy printing of patient data
• Optional roll stand, or wall mounts

Other Specification of Philips Efficia Cardiac Monitor:
BrandPhilips
SeriesEfficia
ModelCM10
Width27 cm (10.6 in)
Height22 cm (6.6 in)
Depth17 cm (6.7 in)
Weight (with no battery)< 3.3 kg (7.0 lb)
DisplayType: 25.6 cm (10.1 in) LCD
Resolution1280 active pixels/line, 800 active lines/frame
Viewing angle± 15
BatteryWeight, 3‑cell, lithium‑ion: 0.25 kg (0.55 lb), 9‑cell, lithium‑ion: 0.5 kg (1.1 lb)
Channels4
Recorder typethermal
Paper width58 mm
User selectable speeds6.25, 12.5, 25 and 50 mm/s
AlarmsThree alarm severity levels (high, medium, low) with corresponding visual and audio indicators
ECG
Heart rate rangeAdult: 15 – 300 bpm, Pediatric and neonatal: 15 – 350 bpm
Heart rate accuracy± 1% or ± 1 bpm
Leads3‑lead and 5‑lead
Pacemaker detectionIndicator of pace pulse on the waveform display 
Invasive blood pressure
Measurement range-40 to 360 mmHg
Input sensitivity5 µV/V/mmHg
Accuracy± 1%
Drift:less than 0.05%/° C
Warm-up time< 15 seconds
Noninvasive blood pressure (NBP)
MethodOscillometric
Adult measurement rangeSystolic: 30 – 270 mmHg (4.0 – 36.0 kPa), Diastolic: 10 – 245 mmHg (1.3 – 32.7 kPa), MAP: 20 – 255 mmHg (2.7 – 34.0 kPa)
Pediatric measurement rangeSystolic: 30 – 180 mmHg (4.0 – 24.0 kPa), Diastolic: 10 – 150 mmHg (1.3 – 20.0 kPa), MAP: 20 – 160 mmHg (2.7 – 21.3 kPa)
Neonatal measurement rangeSystolic: 30 – 130 mmHg (4.0 – 17.3 kPa), Diastolic: 10 – 100 mmHg (1.3 – 13.3 kPa), MAP: 20 – 120 mmHg (2.7 – 16.0 kPa
Blood pressure accuracyMaximum standard deviation: ≤ 8 mmHg, Maximum mean error: ± 5 mmHg
Pulse rate range40 – 300 bpm
Pulse rate accuracy40 – 100 bpm: ± 5 bpm, 101 – 200 bpm: ± 5% of reading, 201 – 300 bpm: ± 10% of reading
Initial cuff inflationAdult: 160 mmHg (21.3 kPa), Pediatric: 140 mmHg (18.7 kPa), Neonatal: 100 mmHg (13.3 kPa)
NBP intervalsAutomatic measurements at intervals of 1, 2, 3, 5, 10, 15, 30, 60, 90, 120 minutes and STAT
Temperature measurements
Measurement range for all measurement sites0° to 50° C (32° to 122° F)
Accuracy± 0.1° C – without a temperature probe
Mode of operation Direct mode
Heating and cooling transient response time≤ 150 s
Microstream CO2
Measurement range0 – 150 mmHg
Data sample rate:Waveform sampling, 20 samples per second
Flow rate 50 ml/min, + 15 ml/min, –7.5 ml/min
CO2 waveform resolution0.1 mmHg
etCO2, imCO2 resolution1.0 mmHg
Initialization and power-up time40 seconds (typical), 3 minutes maximum
Total response time for adults/paediatrics3.9 seconds, for 10% – 90% changes in CO2 concentration
Maximum CO2 response time5.3 seconds (typical)
Calibration intervalInitial calibration after one year or 1,200 hours
Leak tightness< 250 mBar/min
Accuracy (for respiratory rates up to 80 rpm)± 2 mmHg in the range 0 mmHg – 38 mmHg, ± 5% of reading + 0.08% for every 1 mmHg above 38 mmHg in the range 39 mmHg – 150 mmHg
Respiration rate range0 – 150 rpm 
Respiration accuracy± 1 rpm in the range 0 – 70 rpm, ± 2 rpm in the range 71 – 120 rpm, ± 3 rpm in the range 121 – 150 rpm
Effects of cyclical pressureOverpressure: + 100 cmH2O, Underpressure: –20 cmH2O
Mainstream CO2*
Measurement range0 – 150 mmHg**
ImCO2 measurement range3 – 50 mmHg
Data sample rateWaveform sampling, 20 samples per second
CO2 waveform resolution0.1 mmHg
etCO2, imCO2 resolution1.0 mmHg
Initialization timeFull specification etCO2 measurement displays after warm-up, in less than 2 minutes
Total response time< 2 seconds
Calibration intervalNo calibration required
Auto zero intervalOnly required when changing the airway adapter style
Accuracy (gas temperature at 35° C)± 2 mmHg in the range 0 – 40 mmHg, ± 5% of reading in the range 41 - 70 mmHg, ± 8% of reading in the range of 71 – 100 mmHg, ± 10% of reading in the range of 101 – 150 mmHg
Respiration rate range0 – 150 rpm
Respiration rate accuracy± 1 rpm
Drift of measurement accuracyShort-term drift (4 hours of use): does not exceed 0.8 mmHg, Long-term drift (120-hour period): retains accuracy specification
Barometric pressureConfigured by system administrator
Impedance respiration
MethodTransthoracic impedance
Measurement range3 – 150 rpm
Resolution1 rpm
Accuracy± 1 rpm in the range 3 – 120 rpm, ± 2 rpm in the range 121 – 150 rpm
Respiration excitation waveform< 250 μA, 37 kHz nominal
ECG leads usedRA to LL
Display sweep speeds6.25, 12.5, 25, 50 mm/s
Leadoff conditionDetected and displayed
ECG arrhythmia
Respiration excitation waveform< 250 μA, 37 kHz nominal 
Time to alarm for tachycardia< 5.0 seconds
Tall T-wave rejection capabilityTested to a T-wave amplitude of 1.8 mV
Heart rate meter accuracy and response to irregular rhythm
Ventricular bigeminy: 80 bpm, Slow alternating ventricular bigeminy: 60 bpm, Rapid alternating ventricular bigeminy: 120 bpm, Bidirectional systoles: 90 bpm
Time to alarm for cardiac standstill < 10 seconds
Time to alarm for low heart rate< 10 seconds
Time to alarm for high heart rate< 10 seconds
Pacemaker pulse rejectionRejects ± 2–± 700 mV; pulse widths 0.1 – 2.0 ms; with no overshoot 
List of Supplies with Cardiac Multipara Monitor:
Name of accessoriesQuantity
ECG Cable1
Spo2 Sensor1
NIBP Cuff (Adult) with Tube1
Temperature Sensor1
Power Cable1
User Manual1

Features

Estimated Delivery:
5-7Days
Warranty :
  • From Manufatcurer
  • 1 Years

Product Specifications

Color:
White
Parameters:
ECG, RESP, SpO2, PR, NIBP and TEMP

Brand/Manufacturer

Brand:
Philips

Display and User Interface

Screen Size :
  • 10 Inch