OPTI CCA Blood Gas Analyzer Machine , OPTI Medical

HS4619
Save 6%
Hover on image to enlarge
In stock
470,131.00
441,638.00
You save: 28,493.00 (6%)
Price in points: 441638 points
+

Minimum quantity for "OPTI CCA Blood Gas Analyzer Machine , OPTI Medical" is 1.

Product ConditionNew Estimated Delivery5-7Days Warranty From Manufatcurer, On site, 1 Years BrandOPTI Medical

chat with us

Our advantages
  • — 12 months warranty
  • — SMS notification
  • — Return and exchange
  • — Different payment methods
  • — Best price
Payment options
Delivery

Description

The OPTI CCA Blood Gas and Electrolyte Analyzer is a microprocessor-based analyzer that uses discrete sensors called optical electrodes to monitor optical fluorescence (optodes). OPTI CCA Blood Gas and Electrolyte Analyzer required for calibration, sample measurement, and waste containment is contained in a disposable, single-use cassette. Swiping the cassette package through the bar-code reader reads specific calibration information from the cassette into the analyzer. After that, the cassette is inserted into the measuring chamber.

By running a precise calibration gas mixture through the optode sensors, the OPTI CCA Blood Gas Analyzer heats the cassette to 37.0°C (0.1°C)/98.6°F (0.1°F) and performs a calibration verification on the sensors for PCO2 and PO2. Precision buffer solution in the cassette is used to calibrate the pH and electrolyte channels. The analyzer aspirates the blood sample into the cassette and across the optode sensors when the calibration is validated. Fluorescence emission is monitored after equilibration with the blood sample.

Calibration/Measurement

Sample Volume125 µL (60µL for B60 cassette)
Calibration Time<90 seconds
Measurement Time<120 seconds
Typical Cycle Time<210 seconds
Operating Temperature10–30°C (50–86°F)
Sample TypeWhole blood, serum, or plasma
Measurement PrincipleOptical fluorescence, reflectance
Sample ApplicationSyringe, capillary or ComfortSampler
Data Storage
  • 500 patient records
  • 70 QC samples per level
  • 105 SRC samples per level
  • 300 user IDs and passwords

Dimensions/Weight

Height x Width x Depth124 x 362 x 230 mm (4.7 x 14.2 x 9.1 in)
Weight4.3 kg (9.6 lb) with rechargeable battery pack
Miscellaneous
Voltage/Frequency120 or 240 AC, 50–60 Hz
Power Consumption (max.)110 VA
InterfaceASTM, ASCII, POCT protocols via USB or Ethernet
ApprovalsCE, UL, IVDD, and FDA

OPTI CCA-TS2 analyzer specifications:

Measured Parameters: 

  • pH, pCO2, pO2, 
  • Na, K, Cl Ca, 
  • THb, SaO2 
  • GLUCOSE, BUN, LACTATE 

Salient Features: 

  • Storage of reagents at normal room temperature except BUN (2-8°C) and Lactate 
  • Automatic sample aspiration 
  • Portable (lightweight and Mains cum  battery operated with 8 Hrs back-up) 
  • Electronic Quality control 
  • Barcode scanner for quality control information and can be conveniently entered using the on-board bar code scanner 
  • On-Board Thermal printer 
  • Display of results on the in-built  active color touch screen 
  • 200 patient data 
  • RS 232 interface Infrared. ASCII 
  • CE, UL, IVDD Compliant 
  • FDA approved 
  • Up Gradable 

Barometric Pressure: 300–800 mmHg   

Operating Parameters: 

  • Minimum sample size: 125 ul 
  • Sample type: whole blood, serum, plasma 
  • Sample application: Syringe, capillary, or Micro sampler 
  • Sample Input: Automatic Aspiration 
  • Analysis time (time to result) < 120 sec. 
  • Ambient temp: 10°C – 32 °C 
  • Relative Humidity: 5% - 95% (non-condensing) 

Calculated Parameters: 

  • Actual bicarbonate (HCO3), Base Excess (BE) 
  • Base Excess extracellular fluid, Base Excess Actual, Buffer basis (BB), Total CO2: (tCO2) 
  • Standard Bicarbonate, Standard pH(stpH) 
  • Oxygen content (O2ct), Hematocrit (Hct) 
  • Hydrogen ion concentration, Alveolar-Arterial: Oxygen difference (AaDO2),Anion gap(AG) 
  • Standardized ionized Calcium (pH = 7.4), p50 

Input Parameters: 

  • Patient temp, Hemoglobin type ,p50,  FlO2,RQ 
  • Operation ID. Patient ID No., Patient Sex 
  • Mean Corpuscular Hemoglobin Concentration (MCHC),Sample type art/ven/mix, ven/cap/cord/CPB 
  • User-defined field,3 User-defined fields: 
  • Puncture site: left radial, right radial, left brachial, right brachial, left femoral, right femoral, cord, scalp 

Data Management: 

  • Print out: Built-in Thermal printer 
  • Interface: RS 232 C, ASCII or ASTM format 
  • Quality Control Data & standard reference cassette report: 1 month of 3 levels stored onboard. 

Electrical & Gas supply : 

  • Voltage / Frequency: 100 – 250 VAC / 16 VDC, 2.8 A / 50 – 60 Hz. 
  • Power Consumption (Maximum): 110 VA 
  • Battery operation: Up to 8 hrs. (Rechargeable battery pack) 
  • Calibration Gas: Disposable small cylinder 


Features

Estimated Delivery:
5-7Days
Warranty :
  • From Manufatcurer
  • On site
  • 1 Years

Product Specifications

Product Name :
OPTI CCA Blood Gas Analyzer
Model :
OPTI CCA TS2
Qty./BOX:
1

Brand/Manufacturer

Brand:
OPTI Medical

Weight & Dimensions

Product Dimension (mm):
124 mm x 362 mm x 230 mm
Product Weight:
4Kg