Description

The GE Mac 800 ECG machine is an easy-to-use machine that helps you quickly get a resting ECG reading to check heart health. With its EMR-ready solution, you can easily share and store patient information. It is a 6-channel ECG machine that captures detailed heart data and lets you see the ECG reading on the screen before printing, so you can review them carefully.

Key Features of GE MAC 800 ECG machine:

  • Easy Connections: Easily link to MUSE® and CardioSoft™ systems to simplify your ECG tasks and quickly review patient data remotely.
  • Flexible Communication: Choose from different ways to transfer and store ECG data, including LAN, modem, SD card, and serial port, so you can do it from anywhere.
  • USB Convenience: Use USB ports to connect devices like keyboards, printers, barcode scanners, and card readers. You can print full-size ECG reports with the laser printer.
  • Portable Design: The MAC 800 is light at just 6.6 lb. (3.0 kg) and has a built-in handle, making it easy to carry around.
  • Long Battery Life: The lithium-ion battery lasts for two hours of use or 250 patient reports and recharges quickly in about four hours, so you're ready to go in no time.
  • Simple Keypad: The user-friendly keypad, designed like a mobile phone keyboard, makes ECG tasks easier and faster. It's also easy to clean.
  • Clear Display: The 7-inch color screen with high resolution (800 × 480) clearly shows all 12 ECG leads.
  • Onscreen Preview: Check your ECG on the screen before printing to save paper and avoid unnecessary repeat tests.
  • Accurate ECG Analysis: Use the Marquette ECG Analysis Programs for precise and reliable diagnostic results.
  • Smooth EMR Integration: Connect easily to MUSE* and CS Information Management Systems to store, edit, and manage ECG records effortlessly.

 Technical Specifications of GE Mac 800 ECG Machine: 

Product Name

GE Mac 800 ECG Machine

Brand

 GE

Model Name/Number

 Mac 800

Display

7 inches color TFT LCD

Input:

 

Dynamic Range

 ± 10 mV (AC differential signals between any two electrode connections)

±300 mV (superimposed DC voltage - polarization voltage)

Sample Resolution

 4.88μV

Polarization Voltage

 ±300 mV DC

Frequency Response

0.04 Hz -150 Hz

Smallest Detectable Signal

 10 Hz, 20 μVp-p

Recording:


Type

 Thermal dot-matrix printer

Recording Channels

 3 or 6

Resolution (Vertical)

≥ 8 points/mm

Resolution (Horizontal)

 ≥ 16 points/mm, paper speed: 25 mm/s

Speed

 5 mm/s, 25 mm/s, 50 mm/s

Sensitivity/Gain

 2.5 mm/mV, 5 mm/mV, 10 mm/mV, 20 mm/mV, 40 mm/mV ± 5%

Printer Paper

 140 mm x 110 mm (L x W), thermal Z-fold

ECG Processing:

 

ECG Analysis (Option)

 12SL™ adult and pediatric analysis

Storage (Option)

100 or 300 records

Storage Medium (Option)

SD card

Battery Charge Time

 ≤4.5 hours for depleted battery

Storage Temperature

 0°C - 45°C

Temperature

 -30°C - +60°C

Relative Humidity

 10% - 95%

Pressure

 500 hPa -1060 hPa

AC Power Voltage

 100V - 240V, ±10%

AC Power Frequency

 50Hz - 60Hz, +5%, -6%

Fusion

 5×20 mm, F2AL, 250V

Power

 ≤80VA

Internal Battery

 [email protected] AH ±10%, rechargeable Lithium-Ion

Dimensions

 330 mm (Width) x 280 mm (Depth) x 120 mm (Height)

Weight

 3 kg 

  Benefits of GE MAC 800 ECG Machine:

  • Enhance diagnostic confidence with highly accurate, clinically proven Marquette ECG Analysis Programs
  • Streamline your ECG workflow by providing immediate remote review or over-read of patient ECG data
  • EMR communication through its connectivity to MUSE and CS Information Management Systems allows you to store, edit and archive ECG records
  • Increase portability with its lightweight design and integrated carrying handle. Take the GE MAC 800 ECG wherever it’s needed, effortlessly; it weighs 6.6 lb. (3.0 kg) with the battery.
  • Keep your system running at peak performance with tested replaceable accessories, Multi-Link lead wires and disposable electrodes.

Take a Note About GE Mac800 ECG Machine:

  • 6-Channel ECG Machine
  • Long Battery Life
  • Multiple Connectivity Options
  • Onscreen ECG Preview

Quick Tips for GE Mac 800 ECG Machine:

  • Keep it Dry: Ensure the GE Mac 800  ECG machine stays dry and away from liquids. This prevents electrical damage and potential shock hazards to maintain safe operation.
  • Handle Gently: Always handle the machine with care. Avoid dropping or jostling it, as physical shocks can lead to internal damage and malfunction.
  • Inspect Wires: Regularly check all cables and connections for any signs of wear or damage. Replace any frayed or broken cables immediately to ensure accurate readings.
  • Clean Properly: Use a soft, dry cloth to clean the Mac 800 ECG machine. Avoid using harsh chemicals or abrasive materials, as they can damage the machine’s surface and affect performance.
  • Turn Off When Not in Use: Switch off the ECG machine when it’s not being used. This helps conserve energy and prevents overheating, extending the machine’s lifespan.
  • Check Battery Life: If the machine uses batteries, check their level frequently and replace them as needed. Proper battery maintenance ensures the machine operates reliably when required.

Direction of Use for GE Mac 800 ECG Machine:

Power On: Turn on the GE Mac 800 ECG unit by pressing the power button. Wait for the machine to start up and complete its self-check before use.

Prepare Electrodes: Place the electrodes on the patient's chest as shown in the machine's guide. Make sure they are firmly attached to ensure clear readings.

Connect Wires: Attach the ECG leads to the electrodes on the patient. Ensure each lead is connected securely to Mac 800 ECG machine to avoid any signal issues.

Select Settings: Choose the correct settings on the machine for the type of ECG test you require. Follow the onscreen instructions for accurate setup.

Start Recording: Press the start button to start recording the ECG. Keep the patient still and relaxed during the test to get the best results.

Save and Review: After the test, save the ECG results. Review the readings on the screen or print them out for further analysis by a healthcare professional.

Features

Product Specifications

ECG Channel Print:
  • 12 Channel

Brand/Manufacturer

Brand:
GE Healthcare
Find similar