Specification of GE Carescape R860 Ventilator:
Brand | GE |
Model Name/Number | Carescape R860 |
Patient Age Group | Adults, Pediatric Patients, Neonatal |
Tidal Volume | Adult: 100 to 2000 ml, Pediatric: 20 to 300 mlNeonatal: 2 to 50 ml |
Ventilation Modes | A/C VC, A/C PC, A/C PRVC, SIMV VC, SIMV PC, CPAP/PS, SBT, APRV, BiLevel, BiLevel VG, SIMV PRVC, VS, NIV, nCPAP |
Respiratory Rate | Neonatal: 3 to 150 bpm for A/C VC, A/C PC, A/C PRVC; 2 to 60 bpm for SIMV VC, SIMV PC, SIMV PRVC; Off, 1 to 30 bpm for nCPAP Adult/Pediatric: 3 to 120 bpm for A/C VC, A/C PC, A/C PRVC; 1 to 60 bpm for SIMV VC, SIMV PC, SIMV PRVC |
Controls
Trigger | Flow trigger:- Neonatal: 0.2 to 1 L/min (increments of 0.05 L/min), 1 to 3 L/min (increments of 0.1 L/min), 3 to 9 L/min (increments of 0.5 L/min); Adult/Pediatric: 1 to 3 L/min (increments of 0.1 L/min), 3 to 9 L/min (increments of 0.5 L/min) Pressure trigger:- Adult/Pediatric: –10 to –3 cm H₂O (increments of 0.5 cm H₂O), –3 to –0.25 cm H₂O (increments of 0.25 cm H₂O) |
Pressure Support | 0 to 60 cm H₂O for SIMV VC, SIMV PC,SIMV PRVC, BiLevel, BiLevel VG and CPAP/PS (increments of 1 cm H₂O), 0 to 30 cm H₂O for NIV(increments of 1 cm H₂O) |
Flow | Neonatal: 0.2 to 30 L/min, Pediatric: 2 to 72 L/min, Adult: 2 to 160 L/min |
Maximum Peak Flow | Adult: 208 L/min; Pediatric: 100 L/min; Neonatal: 30 L/min |
Inspiratory/ Expiratory Ratio | Neonatal: 1:199 to 40:1 in BiLevel and APRV, Adult/Pediatric: 1:79 to 60:1 in BiLevel and APRV |
Trigger Window | 80% of expiration time |
Bias Flow Rate | Neonatal: 2 to 15 L/min (increments of 0.5 L/min) for nCPAP; Adult/Pediatric: 2 to 10 L/min (increments of 0.5 L/min), 8 to 20 L/min for NIV (increments of 0.5 L/min) |
Settings
Inspiratory Pressure | Neonatal: 1 to 25 cm H₂O (increments of 1 cm H₂O) in nCPAP; Adult/Pediatric: 1 to 98 cm H₂O (increments of 1 cm H₂O) |
PEEP/CPAP | PEEP:- Neonatal: 2-15 cm H₂O (increments of 1 cm H₂O) in nCPAP Adult/Pediatric: Off, 1 to 50 cm H₂O (increments of 1 cm H₂O), 2-20 cm H₂O (increments of 1 cm H₂O) in NIV |
Inspiratory time | Neonatal: 0.1 to 10 sec, 0.1 to 2 sec in nCPAP, 0.1 to 1 sec (increments of 0.01), 1 to 4 sec (increments of 0.1), 4 to 10 sec (increments of 0.25) Adult/Pediatric: 0.25 to 15 sec, 0.25 to 5 sec in NIV, 0.25 to 1 sec (increments of 0.05), 1 to 4 sec (increments of 0.1), 4 to 15 sec (increments of 0.25) |
Expiratory time | Neonatal: 0.25 to 29.9 sec Invasive vent modes, Adult/Pediatric: 0.25 to 59.75 sec |
Monitoring
Peak Inspiratory Pressure | 7 to 100 cm H₂O (increments of 1 cm H₂O), 9 to 100 cm H₂O (increments of 1 cm H₂O)in NIV and nCPAP |
Ambient Conditions
Temperature (device) During Operation | 10° to 40°C |
Relative humidity During Operation | 15 to 95% RH Non-condensing |
Altitude | Operating range: –400 to 3000 m/525 to 800 mmHg , Storage range: –400 to 5860 m/375 to 800 mmHg |
Temperature During Storage & Transportation | –20° to 60°C |
Relative humidity During Storage & Transportation | 15 to 75% RH Non-condensing |
Performance
Intermittent PEEP | High: 1 to 20 cm H2O, Off |
Minute volume | Low: 0.01 to 40 L/min, High: 0.02 to 99 L/min |
Operating Data
Power Consumption | < 200 VA |
Dimensions | 151.77 x 38 x 36 cm |
Weight | 31 kg (not including cart), 78 kg (including cart) |
Power Supply
Battery Type | Lead-acid gel |
Alarm
Inspiratory O₂ concentration (FiO₂) | Low: 18 to 99%, High: 24 to 100%, Off |
Airway Pressure | –20 to +120 cm H₂O |
Apnea alarm time | 5 to 60 seconds |
Audible Alarm Volume Adjustable | 0, 10, 20, and 30 sec, Off |
High Inspiratory Pressure | 1 to 98 cm H₂O (increments of 1 cm H₂O) |
Low Inspiratory Pressure | Off, 1 to 50 cm H₂O (increments of 1 cm H₂O) |
High Respiratory Rate | 2 to 150/min, Off |
Circuit Leak | 10 to 90%, Off |
Escalating Alarms | High priority alarms escalate to a higher pitch if unattended for a specified time |
Auto Limits | Alarm limits calculated on the current measured values for selected parameters |
Display Motion
Vertical Tilt | 162.1° in the raised position, 47.6° in the lowered position |
Height Adjustment | 24.95 cm / 9.8 inch |
Additional Details
Inspiratory Pressure Limit | 7 to 100 cm H₂O for A/C VC and SIMV VC(increments of 1 cm H₂O) |
CO₂ production (VCO₂) | 20 to 1000 mL/min |
Rise time | 0 to 500 ms of the inspiratory period for pressure supported breaths only. Active in SIMV VC, SIMV PC, SIMV PRVC, CPAP/PS, BiLevel VG, BiLevel, and VS (increments of 50 ms) |
Features of GE Carescape R860 Ventilator:
- Lung Protection Strategy
- Innovative user interface
- Menu-free navigation
- Measuring Functional Residual Capacity
Applications GE Carescape R860 Ventilator:
- Emergency Care & ICU
Product Description of GE Carescape R860 Ventilator:
- Ventilator features expert user tools, an innovative user interface, and is inherently familiar the first time you use it.
Featuring expert user tools and an innovative user interface, the Carescape R860 is inherently familiar the first time you use it.
Navigating the past, present, and future states of your ventilated patients is the foundation of the Carescape R860 user interface. From the center workspace view that highlights current patient status, you can swipe left to right to navigate from historical trends on the left (past) to Clinical Decision Support tools on the right (future). Your settings are recalled even as you navigate across workspaces.
By replacing menus with workspace views, the Carescape R860 has flattened the learning curve and unlocked ventilation capabilities by making them more accessible and easier to use.
Features
Reviews
No reviews found
Review this product
Share your thoughts with other customers