Contec 1200G 12 Channel ECG Machine, Touch Screen
Please sign in so that we can notify you about a reply
Description
Key Features of Contec 1200G 12 channel ECG machine :-
1) Sync collection for 12-lead ECG, adopt digital signal processing technology and get high-quality ECG waveform via power frequency filter, baseline filter and EMG filter of ECG signal.
2) Display of 3/6/12-lead ECG, print mode, sensitivity, paper speed and filter state, etc. on one screen, convenient for contrastively diagnosing.
3) Multiply printing modes and formats, including auto 12x1, auto 6x2+1, auto 6x2+1_H, auto 6x2, auto 6x2_H, auto 3x4+1, auto 3x4+2, rhythm 12, rhythm 10, rhythm 8, rhythm 6, manual, etc. Trend chart and histogram of P-R interval can be printed, waveform length printed can be adjusted, and with time print function, which meets different requirements.
4) Paper speed: 5 mm/s, 6.25 mm/s, 10 mm/s, 12.5 mm/s, 25 mm/s, 50 mm/s.
5) Contec 12 Channel ECG Machine with the functions of auto-analysis and auto-diagnosis for routine ECG parameters, provide measurement results and auto-diagnosis conclusion for HR, P-R interval, P Duration, QRS Duration, T Duration, Q-T interval, Q-Tc, P Axis, QRS Axis, T Axis, R(V5), S(V1), R(V5)+S(V1), etc. which reduces the doctor’s burden.
6) Built-in memory stores up to 1000 cases, convenient for case review and statistic.
7) Multi-language(Turkish, French, Chinese, English, German, Kazakstan, Polish, Portuguese, Russian, Slovenian, Spanish and Ukrainian) interface and report.
8) In optimal DC state, up to 10-hour standby time, continuous print more than 3-hour, record up to 300 ECG waveform(commonly, it is 3s case), which meets the requirements of visiting a patient at home and body examination.
Other details of Contec 1200G 12 channel ECG machine:-
-
Input mode: floating and defibrillation protection
-
Frequency response: 0.05Hz ~ 150Hz(-3dB~+0.4dB)
-
CMRR: >60dB, >100dB(add filter)
-
Time constant:≥ 3.2s
-
Patient leak current: <10µA
-
Calibration voltage: 1mV
-
Sensitivity: 2.5, 5, 10, 20, 40 mm/mV ±5%, standard sensitivity: 10mm/mV±2%
-
Noise level: ≤15µVp-p
-
Input circuit current: ≤50nA
-
Input impedance: ≥50MΩ
-
Sampling accuracy: 12-bit
-
Safety classification: class I, type CF and defibrillation-proof applied part
-
Recording mode: thermal printing system
-
Paper size: 210 mm(W)×20 m(L)
-
Sampling frequency: 1000Hz
-
EMG interference filter: 25Hz/35Hz (-3dB)
-
Power frequency filter: AC 50Hz/60Hz(-20dB)
-
Paper speed:
-
Auto: 25, 50 mm/s, ±5%
-
Rhythm: 25, 50 mm/s, ±5%
-
Manual: 5, 6.25, 10, 12.5, 25, 50 mm/s, ±5%
-
Auto record: set record according to auto-record format and mode, automatically switching leads, measuring and analysing.
-
Rhythm record: set record according to rhythm record format and mode, automatically measuring and analysing.
-
Manual record: set record according to record format, manually switching leads.
-
Measurement parameters: HR, P-R interval, P Duration, QRS Duration, T Duration, Q-T interval, Q-Tc, P Axis, QRS Axis, T Axis, R(V5), S(V1), R(V5)+S(V1)
-
Power supply:
-
AC: 100V~240V(50/60Hz)
-
DC: 14.8V/3500mAh, rechargeable lithium battery
-
Fuse specification: two AC time lag fuse(φ5×20 mm), T1.6AL250V
-
Waterproof degree: IPX0
-
Working mode: continuous working
Optional:
ECG-Sync software+USB cable
Physical characteristic of Contec 1200G 12 channel ECG machine
-
Working environment
-
Temperature: 5℃~40℃
-
Relative humidity: 25%~95%(non-condensing)
-
Atmospheric pressure: 700hPa~1060hPa
-
Transport and storage environment
-
Temperature: -40℃~+55℃
-
Relative humidity: ≤95%
-
Atmospheric pressure: 500hPa~1060hPa
-
Dimension: 340 mm(L) × 320 mm(W) × 85 mm(H)
-
Weigh: 3.2Kg
List of Supply with Contec 1200G 12 channel ECG machine :-
Features
- 1 Years
Product Specifications
- 12 Channel
- Up-Down Button
- Measurement
Brand/Manufacturer
Weight & Dimensions
Reviews
No reviews found
Review this product